# Fume Hoods 101: Safety and Efficiency in Modern Labs
Fume hoods are the most critical safety equipment in any laboratory. This comprehensive guide covers everything you need to know about selecting, installing, and maintaining fume hoods.
## Understanding Fume Hood Types
### Ducted Fume Hoods
Ducted fume hoods exhaust contaminated air outside the building through a dedicated duct system.
**Advantages:**
- Removes all contaminants from the laboratory
- Suitable for highly toxic chemicals
- No filter replacement costs
- Higher airflow capacity
**Considerations:**
- Requires external ducting infrastructure
- Higher installation costs
- Energy intensive (conditioned air loss)
- Roof penetration required
**Best For:**
- Pharmaceutical research
- Chemical synthesis laboratories
- University research facilities
- High-volume chemical use
### Ductless Fume Hoods
Ductless (recirculating) fume hoods filter air through activated carbon and HEPA filters before returning it to the laboratory.
**Advantages:**
- No ducting required
- Lower installation costs
- Portable and relocatable
- Energy efficient (no conditioned air loss)
- Faster installation
**Considerations:**
- Regular filter replacement required
- Limited chemical compatibility
- Lower airflow capacity
- Not suitable for highly toxic chemicals
**Best For:**
- Educational laboratories
- Quality control labs
- Low-volume chemical use
- Temporary or mobile setups
### Combination Fume Hoods
Hybrid systems that can operate in both ducted and ductless modes, offering maximum flexibility.
## Key Safety Features
### Face Velocity Control
Face velocity is the speed of air entering the fume hood opening, measured in feet per minute (fpm) or meters per second (m/s).
**Standard Face Velocities:**
- **100 fpm (0.5 m/s):** Standard for most applications
- **80 fpm (0.4 m/s):** Energy-efficient for low-hazard work
- **120 fpm (0.6 m/s):** High-hazard chemical work
**Variable Air Volume (VAV) Systems:**
Modern fume hoods use VAV systems that automatically adjust exhaust volume based on sash position, providing:
- Consistent face velocity
- Energy savings (up to 50%)
- Improved safety
- Reduced operating costs
### Sash Design and Safety
**Vertical Sash:**
- Better protection for upper body
- Easier access to equipment
- Suitable for tall equipment
**Horizontal Sash:**
- Better visibility
- Easier to maintain face velocity
- Compact design
**Combination Sash:**
- Maximum flexibility
- Both vertical and horizontal movement
- Ideal for varied work
### Airflow Monitoring Systems
Modern fume hoods include:
- **Digital Face Velocity Displays:** Real-time monitoring
- **Audible Alarms:** Alert when face velocity is too low
- **Visual Indicators:** LED lights showing safe/unsafe conditions
- **Remote Monitoring:** Integration with building management systems
### Baffles and Airflow Design
Properly designed baffles ensure:
- Uniform airflow across the work surface
- Elimination of dead zones
- Efficient contaminant capture
- Reduced turbulence
## Material Selection
### Work Surface Materials
**Epoxy Resin:**
- Excellent chemical resistance
- Non-porous surface
- Easy to clean
- Long lifespan
- **Best for:** Pharmaceutical and chemical labs
**Stainless Steel:**
- Superior corrosion resistance
- Easy sterilization
- Heat resistant
- **Best for:** Clean rooms and sterile environments
**Phenolic Resin:**
- Good chemical resistance
- Cost-effective
- Durable
- **Best for:** Educational institutions
### Interior Lining Materials
**Polypropylene:**
- Excellent acid resistance
- Lightweight
- Cost-effective
- **Limitations:** Not suitable for organic solvents
**Epoxy-Coated Steel:**
- Good general chemical resistance
- Durable
- Fire resistant
- **Best for:** General chemistry labs
**Stainless Steel:**
- Superior durability
- Easy to clean
- Excellent for perchloric acid work
- **Best for:** High-end research facilities
## Sizing and Placement
### Determining the Right Size
**Standard Widths:**
- 4 feet (1200mm): Single user
- 5 feet (1500mm): One to two users
- 6 feet (1800mm): Two users
- 8 feet (2400mm): Multiple users or large equipment
**Depth Considerations:**
- Standard depth: 30-32 inches (760-810mm)
- Deep fume hoods: 36 inches (915mm) for large equipment
### Laboratory Layout
**Placement Guidelines:**
- Avoid high-traffic areas
- Away from doors and windows
- Minimum 6 feet from room exits
- Not opposite each other (cross-contamination risk)
- Consider natural light (but avoid direct sunlight)
**Spacing Requirements:**
- Minimum 4 feet between fume hoods
- 3 feet clearance in front for wheelchair access
- Adequate ceiling height for ductwork
## Energy Efficiency
### Operating Cost Considerations
A single 6-foot fume hood operating 24/7 can cost:
- **Electricity:** $3,000-5,000 annually
- **Heating/Cooling:** $2,000-4,000 annually
- **Total:** $5,000-9,000 per year
### Energy-Saving Strategies
**1. Occupancy Sensors**
Automatically reduce airflow when hood is not in use:
- 30-50% energy savings
- Maintains minimum safe airflow
- Quick response when user approaches
**2. VAV Systems**
Adjust exhaust based on sash position:
- 40-60% energy savings vs. constant volume
- Maintains consistent face velocity
- Extends equipment life
**3. Sash Management**
Encourage users to close sashes when not in use:
- Simple and effective
- No additional cost
- Immediate energy savings
**4. High-Performance Hoods**
Modern designs with:
- Optimized airflow patterns
- Lower face velocities (80 fpm)
- Better containment
- 20-30% energy savings
## Maintenance and Testing
### Daily Checks (User Responsibility)
- Verify airflow indicator shows safe operation
- Check for obstructions in the hood
- Ensure sash moves smoothly
- Confirm alarm systems are functional
### Monthly Maintenance
- Clean interior surfaces
- Check and clean baffles
- Inspect sash cables and pulleys
- Verify alarm functionality
### Annual Certification
Required by OSHA and ANSI standards:
- **Face velocity testing** at multiple points
- **Smoke pattern testing** for airflow visualization
- **Sash function testing**
- **Alarm calibration**
- **Documentation** of all tests
### Filter Maintenance (Ductless Hoods)
- **Pre-filters:** Replace monthly
- **HEPA filters:** Replace annually or when pressure drop increases
- **Activated carbon:** Replace based on chemical use (3-12 months)
- **Keep records:** Document all filter changes
## Safety Best Practices
### Proper Usage
**DO:**
✓ Keep sash at recommended height (typically 18 inches)
✓ Work at least 6 inches inside the hood
✓ Keep equipment and materials 6 inches from sash
✓ Use fume hood for all volatile chemical work
✓ Clean up spills immediately
**DON'T:**
✗ Store chemicals permanently in the hood
✗ Block baffles or airflow slots
✗ Use hood as a storage cabinet
✗ Perform work outside the sash opening
✗ Disable alarms or monitoring systems
### Emergency Procedures
- Know the location of emergency shut-off
- Understand spill response procedures
- Keep emergency contact numbers visible
- Have spill kits readily available
- Train all users on emergency protocols
## Selecting the Right Fume Hood
### Assessment Checklist
**1. Chemical Compatibility**
- List all chemicals to be used
- Identify most aggressive chemicals
- Determine required material resistance
**2. Usage Patterns**
- Number of users
- Hours of operation per day
- Type of work (synthesis, analysis, teaching)
- Equipment to be used inside hood
**3. Infrastructure**
- Available ductwork
- Electrical capacity
- Space constraints
- Budget considerations
**4. Regulatory Requirements**
- OSHA compliance
- Local building codes
- Industry-specific standards
- Institutional policies
## Global Labs Fume Hood Offerings
### Standard Ducted Fume Hoods
- 4', 5', 6', and 8' widths
- Epoxy resin or stainless steel work surfaces
- VAV-ready design
- Digital airflow monitoring
- 10-year structural warranty
### Walk-In Fume Hoods
- For large equipment
- Floor-mounted design
- Custom sizes available
- Heavy-duty construction
### Perchloric Acid Fume Hoods
- Stainless steel construction
- Wash-down system
- Specialized ductwork
- Safety interlocks
### Radioisotope Fume Hoods
- Lead-lined construction
- HEPA filtration
- Contamination monitoring
- Specialized disposal systems
## Conclusion
Fume hoods are a critical investment in laboratory safety. By understanding the types, features, and maintenance requirements, you can select and operate fume hoods that protect your personnel while optimizing energy efficiency and operational costs.
**Need help selecting the right fume hood?** Contact Global Labs Furniture for expert consultation and customized solutions.
Technical
Fume Hoods 101: Safety and Efficiency in Modern Labs
Technical deep-dive into fume hood types, safety features, maintenance requirements, and how to choose the right fume hood for your laboratory.
Global Labs Team
November 25, 2024
10 min read
# Fume Hoods 101: Safety and Efficiency in Modern Labs
Fume hoods are the most critical safety equipment in any laboratory. This comprehensive guide covers everything you need to know about selecting, installing, and maintaining fume hoods.
## Understanding Fume Hood Types
### Ducted Fume Hoods
Ducted fume hoods exhaust contaminated air outside the building through a dedicated duct system.
**Advantages:**
- Removes all contaminants from the laboratory
- Suitable for highly toxic chemicals
- No filter replacement costs
- Higher airflow capacity
**Considerations:**
- Requires external ducting infrastructure
- Higher installation costs
- Energy intensive (conditioned air loss)
- Roof penetration required
**Best For:**
- Pharmaceutical research
- Chemical synthesis laboratories
- University research facilities
- High-volume chemical use
### Ductless Fume Hoods
Ductless (recirculating) fume hoods filter air through activated carbon and HEPA filters before returning it to the laboratory.
**Advantages:**
- No ducting required
- Lower installation costs
- Portable and relocatable
- Energy efficient (no conditioned air loss)
- Faster installation
**Considerations:**
- Regular filter replacement required
- Limited chemical compatibility
- Lower airflow capacity
- Not suitable for highly toxic chemicals
**Best For:**
- Educational laboratories
- Quality control labs
- Low-volume chemical use
- Temporary or mobile setups
### Combination Fume Hoods
Hybrid systems that can operate in both ducted and ductless modes, offering maximum flexibility.
## Key Safety Features
### Face Velocity Control
Face velocity is the speed of air entering the fume hood opening, measured in feet per minute (fpm) or meters per second (m/s).
**Standard Face Velocities:**
- **100 fpm (0.5 m/s):** Standard for most applications
- **80 fpm (0.4 m/s):** Energy-efficient for low-hazard work
- **120 fpm (0.6 m/s):** High-hazard chemical work
**Variable Air Volume (VAV) Systems:**
Modern fume hoods use VAV systems that automatically adjust exhaust volume based on sash position, providing:
- Consistent face velocity
- Energy savings (up to 50%)
- Improved safety
- Reduced operating costs
### Sash Design and Safety
**Vertical Sash:**
- Better protection for upper body
- Easier access to equipment
- Suitable for tall equipment
**Horizontal Sash:**
- Better visibility
- Easier to maintain face velocity
- Compact design
**Combination Sash:**
- Maximum flexibility
- Both vertical and horizontal movement
- Ideal for varied work
### Airflow Monitoring Systems
Modern fume hoods include:
- **Digital Face Velocity Displays:** Real-time monitoring
- **Audible Alarms:** Alert when face velocity is too low
- **Visual Indicators:** LED lights showing safe/unsafe conditions
- **Remote Monitoring:** Integration with building management systems
### Baffles and Airflow Design
Properly designed baffles ensure:
- Uniform airflow across the work surface
- Elimination of dead zones
- Efficient contaminant capture
- Reduced turbulence
## Material Selection
### Work Surface Materials
**Epoxy Resin:**
- Excellent chemical resistance
- Non-porous surface
- Easy to clean
- Long lifespan
- **Best for:** Pharmaceutical and chemical labs
**Stainless Steel:**
- Superior corrosion resistance
- Easy sterilization
- Heat resistant
- **Best for:** Clean rooms and sterile environments
**Phenolic Resin:**
- Good chemical resistance
- Cost-effective
- Durable
- **Best for:** Educational institutions
### Interior Lining Materials
**Polypropylene:**
- Excellent acid resistance
- Lightweight
- Cost-effective
- **Limitations:** Not suitable for organic solvents
**Epoxy-Coated Steel:**
- Good general chemical resistance
- Durable
- Fire resistant
- **Best for:** General chemistry labs
**Stainless Steel:**
- Superior durability
- Easy to clean
- Excellent for perchloric acid work
- **Best for:** High-end research facilities
## Sizing and Placement
### Determining the Right Size
**Standard Widths:**
- 4 feet (1200mm): Single user
- 5 feet (1500mm): One to two users
- 6 feet (1800mm): Two users
- 8 feet (2400mm): Multiple users or large equipment
**Depth Considerations:**
- Standard depth: 30-32 inches (760-810mm)
- Deep fume hoods: 36 inches (915mm) for large equipment
### Laboratory Layout
**Placement Guidelines:**
- Avoid high-traffic areas
- Away from doors and windows
- Minimum 6 feet from room exits
- Not opposite each other (cross-contamination risk)
- Consider natural light (but avoid direct sunlight)
**Spacing Requirements:**
- Minimum 4 feet between fume hoods
- 3 feet clearance in front for wheelchair access
- Adequate ceiling height for ductwork
## Energy Efficiency
### Operating Cost Considerations
A single 6-foot fume hood operating 24/7 can cost:
- **Electricity:** $3,000-5,000 annually
- **Heating/Cooling:** $2,000-4,000 annually
- **Total:** $5,000-9,000 per year
### Energy-Saving Strategies
**1. Occupancy Sensors**
Automatically reduce airflow when hood is not in use:
- 30-50% energy savings
- Maintains minimum safe airflow
- Quick response when user approaches
**2. VAV Systems**
Adjust exhaust based on sash position:
- 40-60% energy savings vs. constant volume
- Maintains consistent face velocity
- Extends equipment life
**3. Sash Management**
Encourage users to close sashes when not in use:
- Simple and effective
- No additional cost
- Immediate energy savings
**4. High-Performance Hoods**
Modern designs with:
- Optimized airflow patterns
- Lower face velocities (80 fpm)
- Better containment
- 20-30% energy savings
## Maintenance and Testing
### Daily Checks (User Responsibility)
- Verify airflow indicator shows safe operation
- Check for obstructions in the hood
- Ensure sash moves smoothly
- Confirm alarm systems are functional
### Monthly Maintenance
- Clean interior surfaces
- Check and clean baffles
- Inspect sash cables and pulleys
- Verify alarm functionality
### Annual Certification
Required by OSHA and ANSI standards:
- **Face velocity testing** at multiple points
- **Smoke pattern testing** for airflow visualization
- **Sash function testing**
- **Alarm calibration**
- **Documentation** of all tests
### Filter Maintenance (Ductless Hoods)
- **Pre-filters:** Replace monthly
- **HEPA filters:** Replace annually or when pressure drop increases
- **Activated carbon:** Replace based on chemical use (3-12 months)
- **Keep records:** Document all filter changes
## Safety Best Practices
### Proper Usage
**DO:**
✓ Keep sash at recommended height (typically 18 inches)
✓ Work at least 6 inches inside the hood
✓ Keep equipment and materials 6 inches from sash
✓ Use fume hood for all volatile chemical work
✓ Clean up spills immediately
**DON'T:**
✗ Store chemicals permanently in the hood
✗ Block baffles or airflow slots
✗ Use hood as a storage cabinet
✗ Perform work outside the sash opening
✗ Disable alarms or monitoring systems
### Emergency Procedures
- Know the location of emergency shut-off
- Understand spill response procedures
- Keep emergency contact numbers visible
- Have spill kits readily available
- Train all users on emergency protocols
## Selecting the Right Fume Hood
### Assessment Checklist
**1. Chemical Compatibility**
- List all chemicals to be used
- Identify most aggressive chemicals
- Determine required material resistance
**2. Usage Patterns**
- Number of users
- Hours of operation per day
- Type of work (synthesis, analysis, teaching)
- Equipment to be used inside hood
**3. Infrastructure**
- Available ductwork
- Electrical capacity
- Space constraints
- Budget considerations
**4. Regulatory Requirements**
- OSHA compliance
- Local building codes
- Industry-specific standards
- Institutional policies
## Global Labs Fume Hood Offerings
### Standard Ducted Fume Hoods
- 4', 5', 6', and 8' widths
- Epoxy resin or stainless steel work surfaces
- VAV-ready design
- Digital airflow monitoring
- 10-year structural warranty
### Walk-In Fume Hoods
- For large equipment
- Floor-mounted design
- Custom sizes available
- Heavy-duty construction
### Perchloric Acid Fume Hoods
- Stainless steel construction
- Wash-down system
- Specialized ductwork
- Safety interlocks
### Radioisotope Fume Hoods
- Lead-lined construction
- HEPA filtration
- Contamination monitoring
- Specialized disposal systems
## Conclusion
Fume hoods are a critical investment in laboratory safety. By understanding the types, features, and maintenance requirements, you can select and operate fume hoods that protect your personnel while optimizing energy efficiency and operational costs.